HANNA® instruments Catálogo General v38

Customizable User Interface The user interface of the HI5222 allows the user to show measurements in various modes: basic measurement with or without GLP information, real-time graphing, and logging data. Calibration stability criteria can be adjusted to fast, moderate, or accurate. Programmable alarm limits can be set to inside or outside allowable limits. Color Graphic LCD The HI5222 features a color graphic LCD with on-screen help, graphic, and custom color configurations. The display allows for realtime graphing and the use of virtual keys provide for an intuitive user interface. Capacitive Touch The HI5222 features sensitive capacitive touch buttons for accurate keystrokes when navigating menus and screens. There are four dedicated keys that are used for routine operations including calibration and switching measurement modes and four virtual keys that change based upon use. The capacitive touch technology ensures the buttons never get clogged with sample residue. Two Galvanically Isolated pH/ ORP/ISE Channels The HI5222 has two input channels that can be used for pH, ORP, and ISE electrodes. Each input channel has connectors for BNC probes, reference probes, and a temperature sensor. Each channel is galvanically isolated which means that two measurement probes can be in the same solution at the same time and the voltages produced will not interfere with each other. Choice of Calibration Automatic buffer recognition, semi automatic, and direct manual entry pH calibration options are available for calibrating up to five points, from a selection of eight standard buffers and up to five custom buffers. GLP Data HI5222 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data include date, time, buffers used for calibration, and electrode offset and slope characteristics. CAL Check™ CAL Check alerts users to potential problems during the calibration of the pH electrode. Indicators include “Electrode Dirty/Broken,” “Buffer Contaminated,” electrode response time, and the overall probe condition as a percentage that is based on the offset and slope characteristics. ISE Measurement with Choice of Concentration Units The HI5222 allows for calibration and readings in choice of concentration units. The choices of concentration units include ppt, g/L, mg/mL, ppm, mg/L, μg/mL, ppb, μg/L, mg/mL, M, mol/L, mmol/L, %w/v, and a userdefined unit. ISE Measurement with Incremental Methods The known addition, known subtraction, analyte addition, and analyte subtraction incremental methods are pre-programmed into the HI5222. Simply follow the on screen guided procedure and the meter will perform the calculation automatically allowing for a higher level of accuracy to be obtained as compared to a direct ISE measurement. Data Logging Three selectable logging modes are available on the HI5222: automatic, manual, and AutoHold logging. Automatic and manual logs up to 100 lots with 50,000 records max/ lot with up to 100,000 total data points per channel. Automatic logging features the option to save data according to sampling period and interval. Data Transfer Data can be transferred to a PC with USB cable and HI92000 software (both sold separately). Contextual Help Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed. CAL Check Screens 2 pH 2.19 www.hannainst.com | benchtop

RkJQdWJsaXNoZXIy MTI3NTM=