Specifications HI98199 pH / mV (using included HI829113 pH Probe) Range 0.00 to 14.00 pH / ±600.0 mV Resolution 0.01 pH / 0.1 mV Accuracy ±0.02 pH / ±0.5 mV Calibration automatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer EC (using HI763093 EC Probe) Range 0 to 200 mS/cm Resolution manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm Accuracy ±1.5% of reading or ±2 μS/cm whichever is greater Calibration automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point TDS (using HI763093 EC Probe) Range 0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor) Resolution manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L) automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L) Accuracy ±1% of reading or ±1 ppm (mg/L) whichever is greater Calibration based on conductivity calibration Resistivity (using HI763093 EC Probe) Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm Resolution 1 Ω•cm; 0.1 kΩ•cm; 0.0001 MΩ•cm Calibration based on conductivity calibration Salinity (using HI763093 EC Probe) Range 0.00 to 70.00 PSU Resolution 0.01 PSU Accuracy ±2% of reading or ±0.01 PSU whichever is greater Calibration based on conductivity calibration Seawater σ (using HI763093 EC Probe) Range 0.0 to 50.0 σt, σ₀, σ₁₅ Resolution 0.1 σt, σ₀, σ₁₅ Accuracy ±1 σt, σ₀, σ₁₅ Calibration based on conductivity calibration Dissolved Oxygen (using HI764103 DO Probe) Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) Resolution 0.1%; 0.01 ppm (mg/L) Accuracy 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading Calibration automatic one or two points at 0, 100% or one custom point Atmospheric Pressure (using HI764103 DO Probe) Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa Accuracy ±3 mm Hg within ±15°C from the temperature during calibration Calibration automatic at one custom point Temperature Range -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K Resolution 0.01°C; 0.01°F; 0.01K Accuracy ±0.15°C; ±0.27°F; ±0.15K Calibration automatic at one custom point Additional Specifications Temperature Compensation automatic from -5 to 55°C (23 to 131°F) Logging Memory 45000 records (continuous logging or log-on-demand) Logging Interval one second to three hours PC Connectivity via USB (with Hanna PC software) Environment 0 to 50°C (32 to 122°F); RH 100% IP67 Battery Type / Life 1.5V AA batteries (4) / approximately 400 hours of continuous use without backlight (50 hours with backlight) Dimensions / Weight 185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4”) / 400 g (14.2 oz.) Ordering Information HI98199 is supplied with the HI829113 pH digital probe with 4m (13’) cable, pH calibration solution sachets, PC software, micro USB cable, batteries, quality certificate, and instruction manual in a rugged carrying case. Probes HI829113 pH digital probe with 4m (13’) cable HI763093 EC digital probe with 4m (13’) cable HI764103 DO digital probe with 4m (13’) cable Accessories HI710034 orange protective silicone rubber boot HI720199 spare carrying case for HI98199 pH and ORP solutions begin on page 2.158; EC/TDS solutions start on page 5.34 2 pH 2.65 www.hannainst.com | portable

RkJQdWJsaXNoZXIy MTI3NTM=