HANNA® instruments Catálogo General v38

Code HI1217-1 HI1291D Description pH electrode pH electrode Reference single, Ag/AgCl single, Ag/AgCl Junction / Flow Rate ceramic, single ceramic, single Electrolyte gel gel Max Pressure 2 bar 2 bar Range pH: 0 to 12 pH: 0 to 12 Recommended Operating Temp. 0 to 70°C (32 to 158°F) 0 to 70°C (32 to 158°F) Glass Type LT (low temperature) LT (low temperature) Tip /Shape spheric (dia: 5.0 mm) spheric (dia: 5.0 mm) Temperature Sensor yes yes Amplifier yes yes Body Material PEI PEI Cable coaxial; 1 m (3.3’) coaxial; 1 m (3.3’) Recommended Use general purpose general purpose, education, laboratory Connection HI1217-1 DIN** HI1291D DIN** ** Recommended for use with HI8314-1 pH meter 012 mm 110 mm 153.5 mm Special pH and ORP Electrodes ** Recommended for use with HI207 and HI208 pH meters 012 mm 120 mm 163.5 mm Tips for the Most Accurate Measurements Keep Electrode Hydrated Ideally, pH electrodes should be kept in a storage solution when not in use. Placing the electrode in a small glass filled with storage solution is suitable. An option for pocket meters is to place a small piece of sponge into the meter’s cap and pour storage solution into the cap to wet the sponge. Pouring off any excess solution beforehand, the cap can then be placed on the meter. If a storage solution is not available the next best option is to use pH 4.01 buffer (pH 7.01 is also suitable to a lesser extent). Clean Electrodes Before Use Clean the junction of your electrodes once a day or at least once a week to prevent junction clogging and to maintain accuracy. Immerse the electrode in the proper cleaning solution for at least 15 to 20 minutes. Hanna offers a wide range of cleaning solutions for general purpose and specific applications. Replace Electrodes Once a Year If your electrode takes too long to stabilize a reading, or readings fluctuate wildly, it is most likely time to replace the electrode. The typical life span of any pH electrode is from 6 months to 1.5 years. Additional Tips • Calibration and storage solutions should be changed regularly (i.e. monthly). • Calibrate the meter often if a high degree of accuracy is required. • Remember that the calibration is as only as good the buffer being used (i.e. old or contaminated buffer may not have the same value on the label). • Single-use calibration sachets, as opposed to bottles, ensure that your buffer solution is always fresh. • If the meter takes an unusually long time to get a stable reading, the junction may be clogged. • Rinse the probe with purified water after each use. 2 pH 2.143 www.hannainst.com | electrodes

RkJQdWJsaXNoZXIy MTI3NTM=